It is a line of professional devices with a great medical potential, reliability in operation, and a capability to display a large amount of information.

The devices are designed for professional application by general practitioners in outpatient departments, ambulance, as well as at home.

The summary table of parameters
Device parameters, versions
05
04
03
02
01
Diagnostics

Integral dose and null. Sound indication

Integral dose and null. Sound indication
Integral dose and null. Differential dose. Sound and symbolic indication
2 ID modes, 2 screening modes. Integral dose and null. Differential dose. Sound and symbolic indication
2 ID modes, 2 modes of EPD. Integral dose and null. Differential dose. Sound and symbolic indication
Damping
-
-
4 constant modes, 1 variable mode
4 constant modes, 1 variable mode
4 constant modes, 1 variable mode
Amplitude modulation
“1 : 1”
“3 : 1”
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”, BEE
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”, BEE
Frequency modulation
30 - 120 Hz, the cycle time is 8 sec
30 - 120 Hz, the cycle time is 8 sec
30 - 120 Hz, the cycle time is 8 sec, "swing"
30 - 120 Hz, the cycle time is 8 sec, "swing"
30 - 120 Hz, the cycle time is 8 sec, "swing"
Influencing impulse frequencies
60, 120Hz
15, 60, 120, end 350Hz
15…200 Hz every 1Hz, 200…350Hz every 5Hz.
15…200 Hz every 1Hz, 200…350Hz every 5Hz.

15…200 Hz every 1Hz, 200…350Hz every 5Hz.

Intensity (the number of impulses in a packet)
1
1
1 … 8
1 … 8
1 … 8
The duration of gaps between impulses in a packet - Z
-
-
100 … 1300 microsec
100 … 1300 microsec
100 … 1300 microsec
Power
10 … 250 units
1 … 250 units
10 … 250 units
1 … 250 units
1 … 250 units
Indicator
Light-emitting diodes
Graphic LCD
Graphic LCD
Graphic LCD with backlight
Graphic LCD with backlight
Input of personal sets of parameters
-
-
-
Up to 5 sets are saved.
Up to 5 sets are saved.
Setup menu
-
-
-
+
+
Device operation statistics
-
-
-
+
+
Built-in stop-watch
-
-
+
+
+

 

"SCENAR-1-NT" version 01

Specifications:

  • influencing impulse frequency is selected in the range from 15 to 350 Hz;
  • “oscillating frequency” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
  • 4 modes of influencing pulse waveform modification (“damping”);
  • variable pulse waveform (variable damping – var “damping”);
  • “intensive therapy” mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
  • duration of gaps (including variable gaps) between the impulses in each packet can be changed;
  • combined modulation mode (“swing”);
  • several modes of time-dosed high-amplitude influence (a single packet of from 1 to 8 high amplitude impulses) (“like a bee sting” – BEE mode)
  • 2 screening modes; the mode of acupuncture points electroconductivity measuring at alternating current;
  • two algorithms of influence dosing;
  • graphic display of the current reaction dynamics and velocity of its change;
  • a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
  • data display on a graphic LCD with backlight;
  • up to 5 different programs can be saved;
  • built-in stop-watch.

"SCENAR-1-NT" version 02

Specifications:

  • influencing impulse frequency is selected in the range from 15 to 350 Hz;
  • “oscillating frequency” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
  • 4 modes of influencing pulse waveform modification (“damping”);
  • the mode of variable pulse waveform (variable damping – var);
  • “intensive therapy” mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
  • duration of gaps (including variable gaps) between the impulses in each packet can be changed (“Z” submode);
  • combined modulation mode (“swing”);
  • several modes of time-dosed high amplitude influence (a single packet of from 1 to 8 high amplitude impulses) (“like a bee sting” – BEE mode)
  • 1 screening mode;
  • two algorithms of influence dosing;
  • a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
  • data display on a graphic LCD with backlight;
  • built-in stop-watch.

"SCENAR-1-NT" version 03

Specifications:

  • 4 influencing impulse frequencies 15, 60, 120 and 350 Hz;
  • “oscillating frequency” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration of 3 sec and the time gap of 1 sec;
  • one algorithm of influence dosing;
  • graphic display of the current reaction dynamics and velocity of its change;
  • data display on a graphic LCD with backlight.

"SCENAR-2-NT"

Specifications:

  • two influencing impulse frequencies 60 and 120 Hz;
  • “oscillating frequency” mode, the range is 30 to 120 Hz;
  • saw-tooth amplitude modulation;
  • one algorithm of influence dosing;
  • capability to estimate reaction values and reaction coefficient according to the LED indicators states;

Extract from the minutes ¹ 2